Version:
Comfort PRO (Outside 4.204)
Version 4.204 (Jan 2004)
Enhancements
from 4.178
- Enhancements
to work with C-Touch special keypad keys (like End Menu)
- Removed
support for the X10 PL513 one-way interface, which is no longer used
widely. The TW523 or XM10 two way interface is required for X10 interfacing.
- Supports
new Comfort Remote Control RC01
- When downloading
IR code to slave, prevent sending codes which are too large to the slave
which may possibly cause the slave to get stuck in sending IR in certain
situations.
- Broadcasts
Engineer Sign-in to UCM 5.52, reports PS01/00. Used for CWM TCP Pass-through
Port
- Do not
allow messages to be recorded from incoming callers into a mailbox with
no name. In older versions, when the caller hears the list of names
they can select a mailbox that has no name, causing users to be confused
by seeing the new message LED but not knowing how to hear the message.
- Reminders
ON/OFF status are maintained after a RESET, and can now be downloaded
and Uploaded from Comfigurator
- Door Station
Menu will always have 4 to Open Gate 7 to Open door to cater for Door
Station Module (DM01)
- Comfort
broadcasts the date and time when its internal date or time is changed
by any means. This allows external devices to be synchronised to Comforts
real time clock. Comfort also sets its Date and Time from external devices
via the UCM Interface. Date and time changes from UCM is reported in
the event log just like internal change by keypad.
- Events
are always reported to all UCM interfaces, but individual UCMs have
to be logged in to receive the messages on the RS232 port.
- Action
198 Copy Counter added
- When disarming
after an alarm, dialout for System Disarmed Alarm Type is always enabled
even if the System Disarmed dialout is disabled. This allows the System
Disarmed Alarm Type dialout to be disabled normally, while still allowing
dialout when an alarm has just been disarmed.
- Added
support for CBUS Security Application which is needed for C-Touch to
be used as a keypad.
- Comfort
reports the start of Entry and Exit delay to UCM Interfaces - This is
used by UCM/CBUS security application.
- Implemented
Common Mailbox scheme where if Mailbox 1 has no Name recorded, all other
users can access Mailbox 1 messages. If Mailbox 1 has no name recorded,
incoming callers will not hear the prompt "Press 1 for (mailbox 1 name),
2 for (mailbox 2 name), etc.." even though the other mailboxes have
names.
- If there
is a Voice programming error or Vocabulary Failure, the system can still
continue functioning i.e. dialout, record messages, play messages. However
the Voice Menu and announcements will not be heard. Even though Voice
Menu does not announce, the menus can be selected by pressing the keys
on the telephone or keypad. The Event Log will report "Voice Reset"
- In the
case of a failure of the U6 DSP, Comfort will still continue operation,
activate alarms, arm, disarm etc. except that dialouts, recording, playback
of messages, voice menu will not work. Comfort will still work as a
local alarm. The Event Log will report "Voice Reset"
- The strobe
output will automatically turn on for 3 seconds when armed to Local
Away Mode without the need to program via a Response.
- Vocabulary
Download improvements in increasing the time-out for certain operations
(checking the Vocabulary).
- Vacation
Mode has been maintained. It was proposed to combine Vacation Mode with
Away Mode but this was not implemented after the beta program..
Bug Fixes
- When doorbell
rings, but keypad F key is pressed to exit without going into the Door
station menu, at the next reminder message time, the reminder does not
time out, and keeps ringing the phone and chiming keypad without time-out
- When disarming
the system and Low Battery was active but is now restored Low Battery
Led remained always blinking
- Fixed
from 4.147 where SCS or RIO input and output status is not reported
correctly after reset (always off), but subsequent activity of RIO inputs
and outputs correct the status.
- RIO ID
= 8 status of its outputs and inputs was not reported correctly.
- When remote
user on the telephone is entering code and # key to sign in, and local
phone goes offhook, the remote user is able to continue signing in instead
of being connected to the local phone.
- Fixed
Swinger shunt - when zone auto shunt count is exceeded, a zone activation
would not be reported to the CMS but zone restore would still report
if the CMS Report code is enabled (i.e. not FF).
- Fixed
potential problem where too many local phones ringing at the same time
may cause false offhook detection, so that system cannot answer phone
in these cases.
Version
4.193 (Beta - No Warranty) July 2003
- When downloading
IR code to slave, prevent sending codes which are too large to slave
which may cause slave to get stuck in sending IR
- Broadcasts
Engineer Signin to UCM 5.52, reports PS01/00
- Receives
IR codes from Comfort remote control
- Dont allow
messages to be recorded from incoming callers into a mailbox with no
name. Before when caller hears the list of names they can select a mailbox
that has no name, causing users to be confused.
- Fixed
bug where remote user is entering code and # key to sign in, and local
phone goes offhook, the remote user is able to sign in.
- Fixed
bug from 4.136 - Output leds assigned to Home and Armed indicators cause
spurious broadcasts to non-existent ID 60 if their locations are 255.
Also fixed in 4.177
- Fixed
Bug for Digital Input zones - change of input values within on or off
state may lead to activation of on or off response - Aslso fixed in
4.178
- Fixed
Bug Skip did not work in Action 197, ie Action 197 could not be skipped.
Also Fixed in 4.178
- Fixed
bug in Swinger shunt - when zone autoshunt count is exceeded, a zone
activation would not be reported to the CMS but zone restore would still
report if the CMS Report code is enabled (ie not FF).
Version
4.188 (March 2003) (Beta - No Warranty) Replace
ASAP !
- Reminders
ON/OFF status are maintaimed after a RESET, and can now be downloaded
and Uploaded from Comfigurator
- Fixed
bug for common mailbox - when disarming from away mode, there was no
check for common mailbox messages.
- Support
for C-Touch keypad operation for Exit keypad.
- Door Station
Menu will always have 4 to Open Gate 7 to Open door to cater for Door
Station Module (DSM)
- Fixed
potential problem where too many local phones ringing at the same time
may cause false offhook detection, so that system cannot answer phone
in these cases.
Bugs
- Zone
Activation is not detected 1/40 times (serious bug)
- If
Armed/Alarm and Home/Trouble status are 255, there will be a spurious
broadcast to ID 96 (non-existent)
- Digital
Inputs can have multiple activation of ON and Off response
- Action
197 cannot be skipped
- Swinger
shunt - when zone autoshunt count is exceeded, a zone activation
would not be reported to the CMS but zone restore would still report
if the CMS Report code is enabled (ie not FF).
Version
4.182 - January 2003 (Beta - No Warranty) Replace
ASAP !
- Comfort
broadcasts date and time when its internal date or time is changed by
any means. This allows external devices to be synchronised to Comforts
real time clock. Comfort also sets its Date and Time from external devices
via the UCM Interface. Date and time changes from UCM is reported in
the event log just like internal changes.
- Events
are always reported to UCM interfaces, but individual UCMs have to be
logged in to receive the Rs232 messages.
- Action
198 Copy Counter added
- When disarming
after an alarm, dialout is always enabled even if the System
Disarmed dialout is disabled.
- Comfort
reports the start of Entry and Exit delay to UCM Interfaces - This is
used by UCM/CBUS security application.
- Implemented
Common Mailbox scheme where if Mailbox 1 has no Name recorded,
all other users can access Mailbox 1 messages. If Mailbox 1 has no name
recorded, incoming callers will not hear the prompt "Press 1 for (mailbox
1 name), 2 for (mailbox 2 name), etc" even though the other mailboxes
have names.
- If there
is a Voice programming error or Vocabulary Failure, the system can still
continue functioning ie dialout, record messages, play messages. However
the Voice Menu and announcements willl not be heard. Even though Voice
Menu does not announce, the menus can be selected by pressing the keys
on the telephone or keypad. The Event Log will report "Voice Reset"
- In the
case of a failure of the U6 DSP, Comfort will still continue operation,
activate alarms, arm, disarm etc except that dialouts, recording, playback
of messages, voicemenu will not work. Comfort will still work as a local
alarm. The Event Log will report "Voice Reset"
- The strobe
output will automatically turn on for 3 seconds when armed to Local
Away Mode without the need to program via a Response.
- Vocabulary
Download improvements in increasing the timeout for certain operations
(checking the Vocabulary).
- Added
support for CBUS Security Application.
- Vacation
Mode has been combined into Away Mode. There is not separate Vacation
Mode, but the 8 Vacation Programs will run in Away Mode, so Away Moode
will behave like Vacation Mode.
Bugs
- Engineer
menu 3,0 Set Control Group goes to wrong menu - Use Comfigurator
to set Control Group words
- When
disarm from Away or Night from keypad by users 2 to 8, new messages
for common mailbox are not played
- Arming
in Duress will cause Reset
- Zone
Activation is not detected 1/40 times (serious bug)
- If
Armed/Alarm and Home/Trouble status are 255, there will be a spurious
broadcast to ID 96 (non-existent)
- Digital
Inputs can have multiple activation of ON and Off response
- Action
197 cannot be skipped
- Swinger
shunt - when zone autoshunt count is exceeded, a zone activation
would not be reported to the CMS but zone restore would still report
if the CMS Report code is enabled (ie not FF).
Version
4.178 (JE16) 2 June 2003
- Fixed
Bug - If Armed/Alarm and Home/Trouble status are 255, there will be
a spurious broadcast to ID 96 (non-existent)
- Fixed
Bug Digital Inputs can have multiple activation of ON and Off response
- Fixed
Bug Action 197 cannot be skipped
Bugs
- Swinger
shunt - when zone autoshunt count is exceeded, a zone activation would
not be reported to the CMS but zone restore would still report if the
CMS Report code is enabled (ie not FF).
Version
4.177 (JE16) 30 April 2003
- Fixed
bug from 4.172 - zone activation not detected around 1 out of 40
times
Bugs
If Armed/Alarm
and Home/Trouble status are 255, there will be a spurious broadcast to
ID 96 (non-existent)
Digital
Inputs can have multiple activation of ON and Off response
Action 197
cannot be skipped
Swinger
shunt - when zone autoshunt count is exceeded, a zone activation would
not be reported to the CMS but zone restore would still report if the
CMS Report code is enabled (ie not FF).
|