Comfort Comfort Central Processor Gen.2 Panel (EN03) Ultra II
|
|
This version of Comfort Ultra II (CP9000-ULT/EN03) has been designed to comply with PD6662/EN50131 Intruder Alarms for Remote Signalling system which are required to comply with insurance and to summon a Police response (NSA and SSAIB approved installers only). Comfort II is largely compatible with
the old generation of modules and peripherals, allowing an easy upgrade
path for existing customers and installations. For first time buyers theGeneration 1 Comfort Pro is also worth considering.
New Functions
1. Full Duplex Intercom
2. Improved Busy Detection for remote phone hang-up
3. AGC during Recording
4. Built-in Battery Protection
5. Complies with PD6662:2004 Grade 3 Env. Class II (please use the PD6662 .CCT config. file for Comfigurator which is on the CD and in the Technical Area.
|
|
Comfort Ultra 2 Compatability (Gen.2)
|
|
9 -16 zones
|
9 -24 zones*
|
Ringer
|
17 - 64 zones
|
|
|
|
|
|
|
All other Comfort modules are fully
compatible with both G1 and G2 Panels
* If LEM03-G2 is used you are limited to max. 24 zones and 8 outputs.
|
|
Feature Overview
- 8 Inputs/8 Outputs expandable to 64 Inputs/64 Outputs via Slaves
- Addtional 64 Inputs/64 Outputs via RIO/SCS
- 6 Control groups, each with 10 device menus, each with 10 actions
- Full Duplex Intercom between Phones and Keypad/Door Stations (KP03,
KP04 and DP03)
- 1023 Responses with 8 bytes per Response for programming
- 250 Events in Event Log
- 4096 Bytes for Infrared transmit codes (approx 120 IR codes)
- 256 User Counters
- 64 User Flags
- 64 User Timers
- 43 Time Programs
- 16 Reminder Messages
- Supports Remote Input/Output (RIO) and Scene Control Switch (SCS)
for further expansion
- Not yet compliant with EN50131-1/PD6662 but should be in 3rd quarter 2006
|
Description: The new Comfort II (Generation 2) represents
a major advance in performance, useability and technology over the current
generation 1 panels. Some of the advantages include:
- Full Duplex Intercom between phones and keypad/door stations
- Full Duplex Intercom between Keypads and door stations. You can now
talk to the Door station from any keypad.
- Built-in Battery Protection to prevent full battery discharge with
current limiting during charging
- Automatic Gain Control during recording to allow softer messages to
be heard
- Improved detection of busy tone to end remote calls
- Vocabulary Processing tools for customisation of wordlists for zone
and control announcements.
- Onboard mounting of Local Expansion modules (LEM-G2) and Ringer (RGR04).
- Better protection against lighting induced surge voltages
- 32 Time Programs (Ultra II)
- 64 User Timers (Ultra II)
- 16 Reminder Messages (Ultra II)
- Compatible with peripherals on the Comfort Bus - KP, DP, UCM, RIO,
SCS
- Conditional Branch Actions to improve If/Then logic
- New KP03 keypad without LCD and DP03 Door Station
- PCB physical size is the same as old Comfort (more mounting holes)
Upgrade Kit available for G1 panels.
The following includes some enhanced features of Comfort
- 8 Zone Inputs/8 x 12v Outputs expandable to 64 Inputs/64 Outputs
via Slaves (SEP02-M2/230)
- Addtional 64 Inputs/64 Outputs via RIO/SCS
- 6 Home Control groups, each with 10 device menus, each with 10 actions
- All Outputs configurable as IR transmitters.
- 1A regulated DC supply for external devices.
- Full voice menu on telephone or keypad (available in many languages)
- Up to 8 keypads (LCD and non-LCD)
- Dialer with 8 telephone nos to Monitoring Station, telephones, and
Pagers.
- 250 Event log and Alarm History
- 16 user codes with individual user authorisation
- 31 alarm types
- 31 zone types
- Answering Machine with 8 mailboxes
- 32 Time Programs (was 16)
- 16 Reminder messages ring the phone at programmed times((was 8).
- 256 User Counters
- 64 User Flags
- 1023 Responses with 8 bytes per Response for programming
- 4096 Bytes for Infrared transmit codes (approx 120 IR codes)
- Powerful Programmable Responses/Macros
- Programmable by Keypad, phone, or Software
- 2 way X-10 interface (requires XM10E interface)
- Arm to Away, Night, Day, Vacation modes
- False-alarm filtering
- Supervision of phone line, mains, battery
- Webserver for Internet/LAN access available
- Optional GSM Module for security of dial-out and SMS
Keypads, Door Stations, Ringer Module and Battery are sold separately
|
COMPATABILITY
Comfort
Ultra II is NOT compatible with the following Generation 1 products:
RGR03, LEM01, LEM03, for correct operation alternative Generation 2 products
must be used on Comfort II, namely RGR04 ringer, LEM01-M2 and LEM03-M2,
Both G1 and G2 SEP02 Expansion panels may be used with Ultra G2 but
make sure that the correct LEM01 is used .
Existing products SEP02/230,
SEP02/12, RIO-01,
DP01, DP02, DP03, KP01-04, IR and UCM products may all be used with Comfort
G2 range.
Technical resources in the Comfort
Technical Website. |
|
|
|
|
|
|
Comfort G2 Replacement Transformer 230-15V
|
|
Replacement Transformers for G2 Control Panels and SEP's:
230 VAC to 15VAC
|
|
|
|
|
|
Comfort Pro Central Processor Gen.1 (PCB Only) inc. Pro 4.207
|
|
Comfort Pro PCB with version 4.207 Firmware and U4 NVM, Battery lead, terminal block and resistors. This is as a spare part or where Comfort PCB has been damaged by Lightning or is outside of warranty. This board is loaded Pro firmware 4. 207. |
|
|
|
|
|
|
|
|
|
|